Page 7
Always turn the hood ON before cooking in order to establish an air
flow in the kitchen. After turning off the range, let the hood run for a
few minutes to clear the air.
Operate the hood as follows:
OFF
Turns the fan OFF
FAN (1-Pushbutton Switch, 3-Fan Speeds)
Turns the fan ON to the last selected speed, and activates a blue LED
indicating the fan speed setting. Pressing the FAN button a second
time will index the fan speed and LED indicator to the next highest
setting. Pressing the FAN button when the fan is at the highest speed
setting will index the fan and LED indicator to the lowest setting.
DELAY-OFF (10 Minute Delay-OFF)
Activates the 10 minute delay off feature when the fan is ON (any
speed). When activated, the blue LED indicator above the selected
speed setting will blink. The hood fan will automatically turn OFF after
10 minutes has elapsed. The DELAY-OFF button can be pressed at
any time during the 10 minute countdown to turn off the feature.
LIGHT (1-Pushbutton Switch, 3-Light Intensities)
Turns the lights ON to the lowest intensity. Pressing the LIGHT button
a second time will index the light intensity to the next highest level.
Pressing the LIGHT button when the lights are at the highest intensity
will turn the lights off.
FILTER CHANGE INDICATION
After 30 hours of fan operation, the three blue LED indicators will blink
simultaneously, indicating that it is time to clean the grease filters.
To reset the filter clean timer, press and hold the OFF button for 3
seconds. The blinking LED indicators will turn off.
HEAT SENTRY SYSTEM
This range hood is equipped with a standard Heat Sentry system
that monitors excessive temperature and automatically turns the fan
speed on HIGH.
1) If the fan is ON, the Heat Sentry system will increase the fan
setting to its highest speed when the temperature is elevated.
The blue indicator for fan speed (3) will illuminate and blink at
a high rate, indicating that the heat sentry function is activated.
Once the temperature has reduced, the Heat Sentry system will
change the fan speed to the original setting.
2)
If the fan is OFF, the Heat Sentry system will automatically turn the
fan on to its highest speed when the temperature is above normal.
The blue indicator for fan speed (3) will illuminate and blink at a
high rate, indicating that the heat sentry function is activated. After
the temperature has lowered to normal, the fan will turn off.
FUSES
The Range Hood Control Board contains a Main Fuse to protect
the controls from power surges. New fuses can be purchased at a
local electronic supply store. Use 5A, 250V, 5 mm diameter, 20 mm
long, fast-acting, cartridge-type fuses. To replace a fuse (by qualified
person(s): 1. Disconnect power at service entrance. 2. Remove
decorative flues. 3. Remove control cover. 4. Remove and inspect fuse.
OPERATION
OFF FAN
DELAY
OFF
LIGHT
FAN SPEED
LED INDICATORS
12. Measure and install section of flexible metal ductwork
(included with RKE56) to hood duct connector and bottom
of non-duct plenum. Use duct tape to make all joints secure
and air tight.
CAUTION
Do not use plastic duct.
13. Plug power cord into wall outlet.
DUCT LENGTH
DECORATIVE
FLUE
6” ROUND
FLEXIBLE
METAL DUCT
NON-DUCT
PLENUM
14. Slide the upper decorative flue section into the lower
decorative flue section. NOTE For non-ducted applications,
the upper flue should be oriented so the louvers are towards
the ceiling.
15. Carefully place the upper/lower flue assembly into the
recessed area of the hood.
16 Slide the upper flue upward until it is aligned with the non-
duct plenum. The non-duct plenum should be inside the flue.
Secure the upper flue to the non-duct plenum using (2) 4mm
x 12mm mounting screws.
NOTE
9-10 ft. ceilings may require Flue Extension Model
FXNE56SS depending on installation height (purchase
separately). Discard the upper and lower flues supplied
with your hood and replace them with Flue Extension
Model FXNE56SS.