Page 2
INSTALL THE DUCTWORK
(Ducted Hoods Only)
1. Decide where the ductwork will run between the hood and
the outside.
2. A straight, short duct run will allow the hood to perform
most efficiently.
3. Long duct runs, elbows and transitions will reduce the
performance of the hood. Use as few of them as possible.
Larger ducting may be required for best performance with
longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork
to cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
MEASURE THE INSTALLATION
The minimum hood distance above cooktop MUST NOT BE
LESS than 30”.
A maximum of 36” above cooktop is highly recommended for
best capture of cooking impurities.
Distances over 36” are at the installer and users discretion;
providing that the ceiling height permits.
NOTE:
On 8-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 32¼” (for ducted discharge)
Minimum 30”, Maximum 30½” (for non-ducted discharge)
On 9-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for both ducted and non-ducted
discharge).
On 10-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for both ducted and non-ducted
discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model
FXN59SS for ducted or non-ducted installations (purchase
separately).
PREPARE THE HOOD
ROOF
CAP
DECORATIVE
FLUES
EAVE
VENT
6” ROUND
ELBOWS
6” ROUND
DUCT
HOOD
30” TO 36” ABOVE
COOKING SUFACE
HOOD
CENTER
LINE
DUCT CENTER LINE
(1-3/4” to rear of hood
centerline)
Unpack hood and check contents. You should receive:
1 - Hood
1 - Metal Canopy
1 - Decorative Flue Assembly (2 pcs.)
1 - Damper / Duct Connector
1 - Ceiling Mounting Plate
8 - Angle Brackets
2 - Aluminum Grease Filters (installed in hood)
1 - Parts Bag containing:
8 - Mounting Screws (M6 x 40mm Pan Head)
46 - Machine Screws (M4 x 8mm Pan Head)
20 - Serrated Flange Nuts (M4)
8 - Sheet Metal Screws (M4 x 8mm Phillips Head)
3 - Wire Nuts
M4 x
8 mm
M4 x 8 mm
Sheet Metal
M6 x
40 mm
Wire Nut
M4
Serrated
Flange
Nut
Seitenansicht 1