WIRE THE VENTILATOR
WARNING:
SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE
PANEL BEFORE MAKING ELECTRICAL CONNECTIONS.
WHITE
BLACK
120/127 VAC
POWER CABLE
WIRING
BOX
GROUND
TAPE HERE
ATTACH GRILLE
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
1. Attach power cable to electrical wiring box and switch box using
the proper connector for the type of cable being used.
2. Make electrical connections. Connect black to black, white to
white and bare or green wire to electrical wiring box using the
green ground screw.
CONNECT THE DUCT
(FOR WALLS 6" TO 10" THICK ONLY - INCLUDING INSIDE AND
OUTSIDE WALL COVERINGS)
1. Stretch the adjustable duct, slide it over the housing and tape it in
place. (You may need to shorten non-tapered end of flexible duct
to fit.)
INSTALL VENTILATOR IN WALL
1. Place ventilator into wall opening. Re-install electrical wiring box
and cover. Plug motor into receptacle in wiring box cover.
2. Fasten ventilator to inside wall with appropriate screws.
1. From outside, slip adjustable duct into wall cap and tape the joint.
2. Compress the excess duct back into the opening by positioning the
wall cap against the outside wall.
3. Fasten wall cap to outside wall and caulk around the edges.
ON/OFF
SWITCH
TAPE HERE
ATTACH WALL CAP
(FOLLOW STEPS 1 & 2 ONLY IF ADJUSTABLE DUCT IS USED)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects
in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which
is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not
cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This
warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give
the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of
requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
1
2
3
6
7
9
8
3
12
10
11
13
* Standard Hardware - May be purchased locally.
Always order replacement parts by “PART NO." - NOT by “KEY NO.”
1 99110454 Grille
2 99260428 #6-32 Sheet Metal Nut (2 req.)*
3 99170245 #8B x 3/8 Sheet Metal Screw (3 req.)*
4 97005322 Motor Mounting Bracket 97005322
5 99080199 Motor (512M)
99080547 Motor (512MMX)
6 99020125 Blade
7 98004932 Wiring Box Cover
8 99150471 #10-32 x 1/2 Green Ground Screw*
9 98005329 Wiring Box
10 97011741 Housing
11 99270982 Receptacle
12 99610012 Adjustable Duct
13 97011740 Wall Cap
DESCRIPTION
NO.
PART
NO.
KEY
1. Spin grille onto its mounting screw until the
grille is tight against the wall.
2. Turn on the power and check for proper
operation of ventilator.
USE AND CARE
WARNING: SWITCH OFF POWER AT SERVICE PANEL AND LOCK
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS VENTI-
LATOR.
TO CLEAN FAN ASSEMBLY:
Unplug motor from black receptacle. Remove the motor assembly by
loosening the mounting screws and rotating the motor assembly clockwise.
Gently vacuum motor assembly and inside of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN
WATER.
PERIODICALLY CHECK THE OUTER LOUVER FOR ACCUMULATED
DUST, LINT, ETC., WHICH MAY INTERFERE WITH PROPERLOUVER
CLOSURE.
WARNING: DO NOT SPRAY WATER INTO LOUVER-DAMAGE TO
THE FAN COULD OCCUR AND WATER COULD ENTER HOUSE.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
SERVICE PARTS
Models 512M, 512MMX
5